Teilnummer:
Hersteller
Freescale Semiconductor
Infineon Technologies
Melexis Technologies NV
NXP Semiconductors
NXP USA Inc.
STMicroelectronics
Serie
*
-
Automobil, AEC-Q100
Automotive, AEC-Q100
FXPS7115D4
FXPS7165D4
FXPS7250A4
FXPS7250D4
FXPS7400A4
FXPS7400D4
FXPS7550A4
MP3V5004
MP3V5010
MP3V5050
MP3V5100
MP3V7007
MPVZ12
MPVZ2202
MPVZ4006G
MPVZ5004G
MPVZ5010
MPVZ5010G
MPVZ5050G
MPVZ5150
MPX10
MPX12
MPX2010
MPX2050
MPX2053
MPX2100
MPX2102
MPX2200
MPX2202
MPX2300
MPX2301
MPX4080D
MPX4100A
MPX4105A
MPX4115A
MPX4200A
MPX4250
MPX4250A
MPX5010
MPX5050
MPX5100
MPX53
MPX5500
MPX5700
MPX5999
MPXA4100A
MPXA4101A
MPXA4115A
MPXA4250A
MPXA6115A
MPXAZ4100A
MPXAZ4115A
MPXAZ4250A
MPXAZ6115A
MPXH6101A
MPXH6115A
MPXH6250A
MPXH6300A
MPXH6400A
MPXHZ6115A
MPXHZ6116A
MPXHZ6130A
MPXHZ6250A
MPXHZ6400A
MPXM2051G
MPXM2053
MPXM2102
MPXV10
MPXV12
MPXV2010
MPXV2050
MPXV2053
MPXV2102
MPXV4006G
MPXV4115V
MPXV5004
MPXV5010
MPXV5050
MPXV5050V
MPXV5100
MPXV53G
MPXV6115V
MPXV7002
MPXV7007
MPXV7025
Triaxis®
XENSIV™.
Paket
Bag
Band
Band & Spule (TR)
Bulk
Geschnittenes Klebeband (CT)
Rohr
Schnittband (CT)
Schüttgut
Tablett
Tape & Reel (TR)
Tray
Tube
Produktstatus
Active
Aktiv
Bei eingestellt
Discontinued at
Letzter Kauf
Nicht für neue Designs
Obsolete
Veraltet
Anwendungen
-
Board Mount
Brett montieren
Industrial Automation
Industrielle Automatisierung
Medizinische Beatmung
Platinenmontage
Drucktyp
-
Absolut
Absolute
Belüftetes Manometer
Belüftetes Messgerät
Differential
Unterschiedliche
Vakuum
Verbindung
Betriebsdruck
-
-0,25PSI ~ 5PSI (-1,7kPa ~ 34,5kPa)
-0.25PSI ~ 5PSI (-1.7kPa ~ 34.5kPa)
-0.54PSI ~ 0.18PSI (-3.72kPa ~ 1.24kPa)
-0.72PSI ~ 0.72PSI (-4.98kPa ~ 4.98kPa)
-0.87PSI ~ 3.77PSI (-6kPa ~ 26kPa)
-14.5PSI ~ 0PSI (100kPa ~ 0kPa)
-15.23PSI ~ 0.73PSI (-105kPa ~ 5kPa)
-16,68 PSI (-115 kPa)
-17.4PSI ~ 0.73PSI (-120kPa ~ 5kPa)
-1PSI (-6,89kPa)
-2,9PSI ~ 7,25PSI (-20kPa ~ 50kPa)
-2.9PSI ~ 7.25PSI (-20kPa ~ 50kPa)
-4,35PSI ~ 14,5PSI (-30kPa ~ 100kPa)
-4.35PSI ~ 14.5PSI (-30kPa ~ 100kPa)
-7,25 PSI (-50 kPa)
0 ~ 1,45 PSI (0 ~ 10 kPa)
0 ~ 14,5 PSI (0 ~ 100 kPa)
0 ~ 14.50PSI (0 ~ 100kPa)
0 ~ 29,01 PSI (0 ~ 200 kPa)
0 ~ 7.25PSI (0 ~ 50kPa)
0,57 PSI (3,92 kPa)
0,58 ~ 16,68 PSI (4 ~ 115 kPa)
0,58 ~ 20,31 PSI (4 ~ 140 kPa)
0,87 PSI (6 kPa)
1,45 PSI (10 kPa)
1,45 PSI ~ 16,68 PSI (10 kPa ~ 115 kPa)
1,45 PSI ~ 43,51 PSI (10 kPa ~ 300 kPa)
1,45 ~ 4,35 PSI (10 kPa ~ 30 kPa)
1,45 ~ 58,02 PSI (10 kPa ~ 400 kPa)
1,45 ~ 58,02PSI (10kPa ~ 400kPa)
1,45PSI (10kPa)
1.45PSI ~ 16.68PSI (10kPa ~ 115kPa)
1.45PSI ~ 43.51PSI (10kPa ~ 300kPa)
1.45PSI ~ 58.02PSI (10kPa ~ 400kPa)
101,53 PSI (700 kPa)
11,6 PSI (80 kPa)
13,05PSI ~ 220,17PSI (90kPa ~ 1518kPa)
14,5 PSI (100 kPa)
14,5 PSI ~ 203,05 PSI (100 kPa ~ 1400 kPa)
14,5PSI (100kPa)
14.5PSI (100kPa)
145,04 PSI (1000 kPa)
145,04PSI (1000kPa)
145.04 ~ 507.63PSI (1000 ~ 3500kPa)
15PSI (103,42kPa)
2,18 PSI ~ 101,53 PSI (15 kPa ~ 700 kPa)
2,18 PSI ~ 14,79 PSI (15 kPa ~ 102 kPa)
2,18 PSI ~ 15,23 PSI (15 kPa ~ 105 kPa)
2,18 PSI ~ 16,68 PSI (15 kPa ~ 115 kPa)
2,18 PSI ~ 18,85 PSI (15 kPa ~ 130 kPa)
2,18 PSI ~ 46,41 PSI (15 kPa ~ 320 kPa)
2,18 PSI ~ 58,02 PSI (15 kPa ~ 400 kPa)
2,18 ~ 14,79PSI (15 ~ 102kPa)
2,18 ~ 16,68 PSI (15 ~ 115 kPa)
2,18 ~ 16,68PSI (15 ~ 115kPa)
2,9 PSI ~ 15,23 PSI (20 kPa ~ 105 kPa)
2,9 PSI ~ 15,95 PSI (20 kPa ~ 110 kPa)
2,9 PSI ~ 16,68 PSI (20 kPa ~ 115 kPa)
2,9 PSI ~ 29,01 PSI (20 kPa ~ 200 kPa)
2,9 PSI ~ 36,26 PSI (20 kPa ~ 250 kPa)
2,9 PSI ~ 43,51 PSI (20 kPa ~ 300 kPa)
2,9 PSI ~ 44,09 PSI (20 kPa ~ 304 kPa)
2,9 PSI ~ 58,02 PSI (20 kPa ~ 400 kPa)
2,9 PSI ~ 79,77 PSI (20 kPa ~ 550 kPa)
2,9 ~ 15,23 PSI (20 ~ 105 kPa)
2,9 ~ 36,26 PSI (20 ~ 250 kPa)
2,9 ~ 58,02 PSI (20 ~ 400 kPa)
2,9 ~ 58,02PSI (20 ~ 400kPa)
2,9 ~ 79,77 PSI (20 ~ 550 kPa)
2,90 ~ 14,5 PSI (20 ~ 100 kPa)
2,9PSI ~ 11,6PSI (20kPa ~ 80kPa)
2,9PSI ~ 79,77PSI (20kPa ~ 550kPa)
2.9PSI ~ 11.6PSI (20kPa ~ 80kPa)
21,76 PSI (150 kPa)
23,21PSI (160kPa)
29,01 PSI (200 kPa)
29,01PSI (200kPa)
3,77 PSI ~ 18,27 PSI (26 kPa ~ 126 kPa)
3,77 PSI ~ 58,89 PSI (26 kPa ~ 406 kPa)
3,77 ~ 58,89PSI (26 ~ 406kPa)
3,77PSI ~ 58,89PSI (26kPa ~ 406kPa)
36,26 PSI (250 kPa)
4,35 PSI ~ 17,4 PSI (30 kPa ~ 120 kPa)
43.51PSI (300kPa)
435.11 ~ 725.19PSI (3000 ~ 5000kPa)
5,8 PSI (40 kPa)
5,8 PSI ~ 16,68 PSI (40 kPa ~ 115 kPa)
5,8 PSI ~ 20,31 PSI (40 kPa ~ 140 kPa)
5,8PSI ~ 16,68PSI (40kPa ~ 115kPa)
58,02PSI (400kPa)
58.02PSI (400kPa)
7,25 PSI (50 kPa)
7,25 PSI ~ 15,95 PSI (50 kPa ~ 110 kPa)
7,25 PSI ~ 16,68 PSI (50 kPa ~ 115 kPa)
7,25 PSI ~ 21,76 PSI (50 kPa ~ 150 kPa)
7,25 PSI ~ 58,02 PSI (50 kPa ~ 400 kPa)
7,25PSI (50kPa)
7,77 PSI ~ 15,95 PSI (53,6 kPa ~ 110 kPa)
7,77PSI ~ 15,95PSI (53,6kPa ~ 110kPa)
72,52 PSI (500 kPa)
7PSI (50kPa)
8,7 PSI ~ 23,93 PSI (60 kPa ~ 165 kPa)
8,7 PSI ~ 37,71 PSI (60 kPa ~ 260 kPa)
8,7 ~ 23,93 PSI (60 ~ 165 kPa)
8,7PSI (60kPa)
8,7PSI ~ 23,93PSI (60kPa ~ 165kPa)
870,2PSI (6000kPa)
±0,29 PSI (±2 kPa)
±1,02 PSI (±7 kPa)
±3,63 PSI (±25 kPa)
Ausgabetyp
-
Analog Voltage
Analog, SENT
Analoge Spannung
Digital - I²C
GESENDET
I²C
I²C, MIPI I3C
I²C, MIPI I3C, SPI
I²C, SPI
RF
SENT
SPI
Wheatstone-Brücke
Ausgang
-
0 mV ~ 120 mV
0 mV ~ 130 mV
0 mV ~ 200 mV
0 mV ~ 25 mV (10 V)
0 mV ~ 3,006 mV (6 V)
0 mV ~ 35 mV (3 V)
0 mV ~ 40 mV
0 mV ~ 40 mV (10 V)
0 mV ~ 40 mV (10V)
0 mV ~ 40 mV (12V)
0 mV ~ 45 mV
0 mV ~ 55 mV (3 V)
0 mV ~ 60 mV (3 V)
0 mV ~ 65 mV (3 V)
0 mV ~ 70 mV
0 V ~ 4,6 V
0,06 V ~ 2,82 V
0,1 V ~ 3,1 V
0,1 V ~ 4,6 V
0,1 V ~ 4,85 V
0,12 V ~ 2,8 V
0,18 V ~ 4,65 V
0,2 V ~ 4,6 V
0,2 V ~ 4,7 V
0,2 V ~ 4,8 V
0,2 V ~ 4,9 V
0,2 V ~ 5 V
0,25 V ~ 4,95 V
0,25V ~ 4,95V
0,3 V ~ 4,6 V
0,3 V ~ 4,7 V
0,3 V ~ 4,9 V
0,3 V ~ 49 V
0,399 V ~ 4,645 V
0,4 V ~ 4,65 V
0,5 V ~ 4,5 V
0,5 V ~ 4,55 V
0,6 V ~ 3 V
0,6 V ~ 4,9 V
0.4 V ~ 4.65 V
0.5 V ~ 4.5 V
0.5 V ~ 5 V
0.5V ~ 4.5V
1 V ~ 4,9 V
1,33 V ~ 4,7 V
10 b
100 mV ~ 3,1 V
12 b
14 b
16 b
200 mV ~ 4,7 V
24 b
24 v
32 b
38,5 V ~ 41,5 V
4,82 V ~ 4,98 V
7 b
Genauigkeit
-
-0,6 % ~ 0,4 %
±0,003 PSI (±0,02 kPa)
±0,007 PSI (±0,05 kPa)
±0,007PSI (±0,05kPa)
±0,01 PSI (0,05 kPa)
±0,01 PSI (0,1 kPa)
±0,015 PSI (±0,1 kPa)
±0,01PSI (0,05kPa)
±0,058 PSI (±0,4 kPa)
±0,1 %
±0,11 PSI (±0,75 kPa)
±0,145 PSI (±1 kPa)
±0,145PSI (±1kPa)
±0,15 PSI (±1 kPa)
±0,174 PSI (±1,2 kPa)
±0,25 %
±0,25 PSI (±1,75 kPa)
±0,29 PSI (2 kPa)
±0,29 PSI (±2 kPa)
±0,3 %
±0,3 PSI (±2,07 kPa)
±0,333 PSI (±2,3 kPa)
±0,345 PSI (±2,38 kPa)
±0,348 PSI (±2,4 kPa)
±0,35 PSI (±2,38 kPa)
±0,435 PSI (±3 kPa)
±0,44 PSI (±3 kPa)
±0,493 PSI (±3,4 kPa)
±0,4°C
±0,51 PSI (3,5 kPa)
±0,51 PSI (±3,5 kPa)
±0,54 PSI (±3,75 kPa)
±0,544 PSI (±3,75 kPa)
±0,580 PSI (±4 kPa)
±0,5°C
±0,65 PSI (4,50 kPa)
±0,652 PSI (±4,5 kPa)
±0,65PSI (4,50kPa)
±0,77 %
±0,81 PSI (5,6 kPa)
±0,83 PSI (5,7 kPa)
±0,87 PSI (±6 kPa)
±0.03PSI (±0.2kPa)
±0.5%
±0.77%
±1 %
±1,015 PSI (±7 kPa)
±1,03 %
±1,16 PSI (8 kPa)
±1,4 %
±1,5 %
±1,72 %
±1,8 %
±1.5%
±10 %
±2,5 %
±2.5%
±3 %
±3%
±5 %
±6,25 %
±7 %
Spannungsversorgung
-
1,2V ~ 3,6V
1,7 V ~ 3,6 V
1,7V ~ 3,6V
1,95 V ~ 3,6 V
10V ~ 16V
12V
16V
2,375 V ~ 5,5 V
2,5V
2,7 V ~ 3,3 V
3,1 V ~ 5,25 V
3,135 V ~ 3,465 V
3,1V ~ 5,25V
3,3 V, 5 V
3,6V
3V ~ 10V
3V ~ 5,25V
3V ~ 6V
4,5 V ~ 11 V
4,5 V ~ 5,5 V
4,5V ~ 11V
4,5V ~ 5,5V
4,64 V ~ 5,36 V
4,64V ~ 5,36V
4,74 V ~ 5,46 V
4,75 V ~ 5,25 V
4,75 V ~ 5,5 V
4,85 V ~ 5,35 V
4.5V ~ 5.5V
6V ~ 10V
- Lageroptionen
- Medien
Alle anwenden
Produkte-725 Rekord(e)
Spalten anpassenHersteller-Teilenummer | Preis (€) | Verfügbare Menge | Serie | Paket | Produktstatus | Anwendungen | Drucktyp | Betriebsdruck | Ausgabetyp | Ausgang | Genauigkeit | Spannungsversorgung | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
€8.28 | 3800 | MPX2010 | Tablett | Aktiv | Platinenmontage | Differential | 1,45 PSI (10 kPa) | Wheatstone-Brücke | 0 mV ~ 25 mV (10 V) | ±1 % | 10V ~ 16V | ||
€10.19 | 9000 | - | Band | Veraltet | Platinenmontage | Absolut | 7,25 PSI ~ 16,68 PSI (50 kPa ~ 115 kPa) | I²C | 10 b | ±0,145 PSI (±1 kPa) | 2,375 V ~ 5,5 V | ||
€3.31 | 20000 | MPX2202 | Tablett | Aktiv | Platinenmontage | Belüftetes Messgerät | 29,01 PSI (200 kPa) | Wheatstone-Brücke | 0 mV ~ 40 mV (10 V) | - | 10V ~ 16V | ||
Preis verhandelbar | 4478 | MPXH6400A | Rohr | Veraltet | Platinenmontage | Absolut | 2,9 PSI ~ 58,02 PSI (20 kPa ~ 400 kPa) | Analoge Spannung | 0,2 V ~ 4,8 V | ±1,5 % | 4,64 V ~ 5,36 V | ||
€11.19 | 4810 | MPXH6250A | Band | Aktiv | Platinenmontage | Absolut | 2,9 PSI ~ 36,26 PSI (20 kPa ~ 250 kPa) | Analoge Spannung | 0,3 V ~ 4,9 V | ±1,5 % | 4,74 V ~ 5,46 V | ||
€17.73 | 3797 | MPVZ5004G | Band | Aktiv | Platinenmontage | Belüftetes Messgerät | 0,57 PSI (3,92 kPa) | Analoge Spannung | 1 V ~ 4,9 V | ±6,25 % | 4,75 V ~ 5,25 V | ||
Preis verhandelbar | 3825 | MPXV7025 | Tablett | Veraltet | Platinenmontage | Verbindung | ±3,63 PSI (±25 kPa) | Analoge Spannung | 0,2 V ~ 4,7 V | ±5 % | 4,75 V ~ 5,25 V | ||
€9.59 | 3322 | MPXH6400A | Band | Aktiv | Platinenmontage | Absolut | 2,9 PSI ~ 58,02 PSI (20 kPa ~ 400 kPa) | Analoge Spannung | 0,2 V ~ 4,8 V | ±1,5 % | 4,64 V ~ 5,36 V | ||
€10.52 | 600 | MPXH6250A | Band | Aktiv | Platinenmontage | Absolut | 2,9 PSI ~ 36,26 PSI (20 kPa ~ 250 kPa) | Analoge Spannung | 0,3 V ~ 4,9 V | ±1,5 % | 4,74 V ~ 5,46 V | ||
€1.91 | 2241 | - | Band | Aktiv | - | - | - | - | - | - | - | ||
€19.11 | 1300 | MPX5700 | Tablett | Aktiv | Platinenmontage | Differential | 101,53 PSI (700 kPa) | Analoge Spannung | 0,2 V ~ 4,7 V | ±2,5 % | 4,75 V ~ 5,25 V | ||
€1.91 | 53724 | - | Band | Veraltet | Platinenmontage | Absolut | 7,25 PSI ~ 15,95 PSI (50 kPa ~ 110 kPa) | I²C | 24 v | ±0,058 PSI (±0,4 kPa) | 1,95 V ~ 3,6 V | ||
Preis verhandelbar | 2630 | MPXA4250A | Band | Veraltet | Platinenmontage | Absolut | 2,9 PSI ~ 36,26 PSI (20 kPa ~ 250 kPa) | Analoge Spannung | 0,2 V ~ 4,9 V | ±1,5 % | 4,85 V ~ 5,35 V | ||
€12.40 | 800 | MPX2202 | Band | Aktiv | Platinenmontage | Belüftetes Messgerät | 29,01 PSI (200 kPa) | Wheatstone-Brücke | 0 mV ~ 40 mV (10 V) | - | 10V ~ 16V | ||
€19.11 | 960 | MPXV7007 | Rohr | Aktiv | Platinenmontage | Verbindung | ±1,02 PSI (±7 kPa) | Analoge Spannung | 0,5 V ~ 4,5 V | ±5 % | 4,75 V ~ 5,25 V | ||
Preis verhandelbar | 4732 | MPXV5010 | Rohr | Veraltet | Platinenmontage | Belüftetes Messgerät | 1,45 PSI (10 kPa) | Analoge Spannung | 0,2 V ~ 4,7 V | ±5 % | 4,75 V ~ 5,25 V | ||
Preis verhandelbar | 2712 | - | Band | Veraltet | - | Absolut | 2,9 PSI ~ 36,26 PSI (20 kPa ~ 250 kPa) | I²C | 32 b | ±0,51 PSI (±3,5 kPa) | 3,1 V ~ 5,25 V | ||
Preis verhandelbar | 4578 | - | Band | Veraltet | - | Absolut | 5,8 PSI ~ 16,68 PSI (40 kPa ~ 115 kPa) | I²C | 32 b | ±0,25 PSI (±1,75 kPa) | 3,1 V ~ 5,25 V | ||
Preis verhandelbar | 2685 | - | Band | Veraltet | - | Absolut | 2,9 PSI ~ 58,02 PSI (20 kPa ~ 400 kPa) | I²C | 32 b | ±0,51 PSI (±3,5 kPa) | 3,1 V ~ 5,25 V | ||
€10.14 | 5000 | MPXV5004 | Band | Aktiv | Platinenmontage | Belüftetes Messgerät | 0,57 PSI (3,92 kPa) | Analoge Spannung | 1 V ~ 4,9 V | - | 4,75 V ~ 5,25 V | ||
€4.17 | 4050 | - | Band | Veraltet | Platinenmontage | Absolut | 8,7 PSI ~ 23,93 PSI (60 kPa ~ 165 kPa) | Analoge Spannung | 0,2 V ~ 4,8 V | ±0,145 PSI (±1 kPa) | 4,5 V ~ 5,5 V | ||
Preis verhandelbar | 4409 | MPVZ5010G | Rohr | Veraltet | Platinenmontage | Belüftetes Messgerät | 1,45 PSI (10 kPa) | Analoge Spannung | 0,2 V ~ 4,7 V | - | 4,75 V ~ 5,25 V | ||
Preis verhandelbar | 50 | MPXV5004 | Schüttgut | Veraltet | Platinenmontage | Belüftetes Messgerät | 0,57 PSI (3,92 kPa) | Analoge Spannung | 1 V ~ 4,9 V | - | 4,75 V ~ 5,25 V | ||
Preis verhandelbar | 2401 | MPXV4006G | Rohr | Veraltet | Platinenmontage | Belüftetes Messgerät | 0,87 PSI (6 kPa) | Analoge Spannung | 0,2 V ~ 4,7 V | ±5 % | 4,75 V ~ 5,25 V | ||
€17.20 | 311 | MPX2010 | Tablett | Aktiv | Platinenmontage | Differential | 1,45 PSI (10 kPa) | Wheatstone-Brücke | 0 mV ~ 25 mV (10 V) | ±1 % | 10V ~ 16V |
Hersteller-Teilenummer | |
---|---|